R1300 - The Universal Controller - Flexible - Compact - Powerful

R1300 - The Universal Controller - Flexible - Compact - Powerful

Clarian R1300 (PDF datasheet). Product enquiry and further information (Contact us form).

The R1300 is the universal controller for custom applications. It has continuous inputs and outputs, is available as a 3-point step controller and can be expanded with data interfaces.

Technical Data

Input Thermocouple:

  • Built-in internal compensation point and protection against sensor breakage and incorrect polarity.
  • Re-calibration not required for a line resistance of up to 50 Ohms.
  • Calibration accuracy: < 0,25%

Input RTD, Pt 100 (DIN):

  • 2- or 3- wire connection possible.
  • Built-in protection against sensor breakage and short circuit.
  • Max. permissible line resistance by 3-wire connection: 80 Ohms
  • Sensor current: < 0,5 mA
  • Calibration accuracy: < 0,2 %

Linear error: < 0,2 %
Influence of the ambient temperature: < 0,01 % / K

Setpoint selection:

Ext. potential-free contact, switching voltage appr. 24 V dc, max. 1 mA. Selection between SP1 and SP2 or between SP1 and the analogue setpoint signal SPA.

Control outputs:

  • OUT 1:
    • Relay (UR appr.), (changeover contact) max. 250 Vac, max. 3 A (resistive load) and bist. voltage signal, 0/18 V dc, max. 10 mA, short-circuit proof
  • OUT 2:
    • Relay (UR appr.), (changeover contact) max. 250 Vac, max. 3 A (resistive load) and bist. voltage signal, 0/18 V dc, max. 10 mA, short-circuit proof
  • OUT 4 or OUT 5:
    • Continuous ( version > R1300-2) The output signal (current or voltage) is determinated automatically, dependand on load.
    • 0/4...20 mA, load of max. 500 Ohm
    • 0/2...10 V dc, load of > 1 k-Ohm
    • Linearity: < 1,5 %
    • Delay time: app. 2 secs.

Alarm output:

  • OUT 2:
    • Relay (UR appr.), (changeover contact) max. 250 Vac, max. 3 A (resistive load). Only for 2-point-controller and continuous-controller configuration.
  • OUT 3:
    • Relay (UR appr.), (changeover contact) max. 250 Vac, max. 3 A (resistive load).

Setpoint input:
(analogue)

  • (Only version R1300-3), equivalent to the choosen range
  • 0...10 V dc
  • 0...20 mA
  • 4...20 mA

Process output:
(analogue)

  • OUT4 or OUT5:
    • (Only version R1300-3), equivalent to the choosen range
    • 0...10 V dc
    • 0...20 mA
    • 4...20mA
    • Load max. 500 Ohms

Ser. Interface:

  • ( > version R1300-2) RS 485, Protokoll: Standard (RS232: Option)

7-Segment-Display:

  • Process: 10 mm red, Set: 10 mm red

Data protection:

  • EAROM

CE-Mark

  • Tested according to 2004/108/EC; EN 61326-1, industrial ares
  • Electr. safety: EN 61010-1

Power supply:

  • Standard: 230 V ac, (internal jumper 115 V ac). Others possible. See Type Code. ± 10 %, 48...62 Hz

Connections:

  • Screw terminals (UR appr.). Protection mode IP 20 (DIN 40050), Insulation class C.

Permissible operating conditions:

  • Operating temperature:
    • 0...50 °C / 32...122 °F
  • Storage temperature:
    • -30...70 °C / -22...158 °F
  • Climate class:
    • KWF DIN 40040; equivalent to annual average max. 75 % rel. humidity, no condensation

Casing:

  • Format:
    • 96 x 96 mm (DIN 43700), installation deepth 122 mm
  • Panel cutout:
    • 92 +0,5 mm x 92 +0,5 mm
  • Material:
    • Noryl, self-extinguishing, non-drip, UL 94-V1
  • Protection mode:
    • IP 20 (DIN 40050),
    • IP 50 front side

Weight:

  • app. 650g (R1300-1); app. 800g (R1300-2, R1300-3)

Subject to technical improvments!